Raypak gas pool heaters with a digital display show short phrases, such as Water Sw Open. Some phrases are normal steps, like No Demand. Others report a fault. The same phrase can mean something else on another model. A phrase points to what the heater sensed, not to a failed part. The message lookup below explains each phrase by model, with the manual page.
The Digital and the AVIA can both show Ign 60 min Delay, but the cause differs. On an AVIA, it comes after three failed tries to light the burner in one call for heat (AVIA manual, p. 36). That alone does not show why. Raypak's guide for it checks the wiring, the gas supply, the gas valve and the spark igniter (p. 51).
On a Digital heater, the manual lists this message for just one control setup inside the heater. There it means the pilot kept going out. A pilot is a small flame that lights the main burner. The screen also switches back and forth with Main Ign Failure (Digital manual, p. 28). Write down both messages and the model. Ask a technician to find the cause.